The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays plants and other decorative elements that prevent wheelchair users and others from reaching.
Minimum clear floor space definition.
Equipment such as raceways cables wireways cabinets and panels can be above or below electrical equipment but must not extend more than 6 in.
Advisory 407 2 1 3 clear floor or ground space.
Working space covered by 110 26 must be clear at all times 110 26 b.
Knee and toe space is required below drinking fountains lavatories and sinks dining and work surfaces and those sales and service counters that provide a forward approach.
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
Clear space and minimum size.
The minimum depth of the lavatory is 17 inches 430 mm.
Definition of clear space.
Clear floor space sizes clear floor spaces are typically 30 x 48 minimum unless blocked on all or part of three sides for more than half the distance.
Clear space is defined as the space that no other element explicit or implicit shall cross in relation to the university logo.
Clear floor space at lavatories.
In all cases the minimum depth may be further determined by the required reach to operable parts served by the clear floor space.
See the definition of dwelling unit in art.
A clear floor or ground space complying with 305 shall be provided at call controls.
The clear floor space shall extend up to 19 inches 485 mm maximum into the kneespace below the lavatory.
Into the equipment working space 110 26 a 3 fig.
Introducing the new and improved ada 2010.
If blocked by objects or within an alcove then the clear floor space increases from 30 x 48 to either 36 x 48 or 60 x 30.
Patient dressing rooms must provide a 30 inch by 48 inch wheelchair clear floor space at the end of a 20 inch by 42 inch bench making the space a minimum of 40 square feet.
Key changes in the latest ada standards will impact healthcare design.
A clear floor space at least 30 inches 760 mm wide and 48 inches 1220 mm long is required for a forward approach in front of the accessible lavatory.
The turning space shall be a t shaped space within a 60 inch 1525 mm square minimum with arms and base 36 inches 915 mm wide minimum.
The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.